    *** For Auction ***
    * EF Johnson Viking II AM/CW transmitter, rebuild started
    * Unit stripped to chassis, Chassis cleaned, degreased, scrubbed, dents removed
    * All terminal strips replaced
    * Tube socket replacement underway.
    * HV & LV rectifier tube sockets replaced with amphenol units.
    * All tube sockets replaced
    * Under-chassis re-wire approximately 20% complete.
    * So far, in the wiring rebuild, we have found 6 un-soldered connections and two mis-wires.
    * Tube heater wiring circuit completed
    * Tube heater circuit test
    * Bias rectifier and divider circuit test
    * Top of chassis shield installed
    * IEC three conductor AC Line cord installed
    * Power (heater) panel switch circuit tested
    * HV power transformer installed
    * HV filter capacitor/bleeder assembly installed
    * Microphone input circuit wiring completed
    * Clamp circuit resistor mounted on chassis
    * RF Oscillator & Buffer circuitry wiring completed
    * PA Tuning components support bar replaced ( we use copper bar for this)
    * PTT module installed and tested
    * Voltage Regulator / Driver/ Bias module installed
    * RF amplifier section installed
    * PA Tubes sockets wiring installed
    * Roller Inductor input shaft extended bushing installed
    * PA tuning and loading capacitors installed
    * New drive potentiometer installed, control wiring installed
    * HV Choke, Modulation transformer, LV choke installed
    * LV +300VDC regulator circuit test
    * Adjustable modulator bias circuit tested
    * LV circuit test
    * +300V distribution circuitry tested
    * PA shunt HV choke installed, shunt choke bypass capacitors and safety choke installed
    * HV rectifier (2) heater circuit tested
    * PTT module function test from panel mic connector.
    * Modulation transformer installed
    * Installed AC line fuse holder and fuse, 6A 3AG SB, for  (T2) HV transformer
    * Installed temporary panel meter
    * Replaced + common contact on meter switch
    * RF amplifier chain circuit tested up to PA Grid. Metering and levels test: Osc,Buff,Grid metering tested.Circuit tested with 40 meter crystal .
    * All transformers installed with vibration proof hardware stack: 8-32 machine screw, internal tooth lock washer, 3/8" X #8 washer, 3/4" X #8 washer, #8 keps nut.
    * Modulator microphone preamplifier circuit tested to modulator tube grids. Mic gain contol circuit tested
    * T2 Primary circuit tested with "Plate"switch and PTT relay.
    * Installed RF output cable assembly ( RG/8AU)
    * Power pilot lamp ( LED Assembly) installed and tested
    * Modulator tubes anode components installed
    * Installed VFO Input cable assembly
    * Installed new PA suppressor assemblies (2) and new PA Plate/PA RF Choke interconnect assembly
    * Electronic rebuild complete, waiting on panel re-paint & re-decal.
    * All Sales Final, No warranties or guarantees expressed or implied, no returns
    * After sale technical support via Email
    * No shipping: Local pickup or arranged shipping only. Send us a pre-built crate and we will gladly      pack the unit into your crate and have it picked up by a shipper. Not sure of the dimensions of a crate ? Email us.